为了使您在Abcam官网的浏览体验更顺畅,请使用最新版本的浏览器比如 Google Chrome

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
致电 +86 21 2070 0500 或 联系我们

  • 我的账户
  • 退出
登录 或 注册

欢迎光临

登录 或

您还没有帐户?

注册
我的购物篮
快速订购
Abcam homepage

  • 研究用途的产品
    按产品类型
    一抗
    二抗
    免疫测定试剂盒与试剂
    细胞与组织成像工具
    细胞与生化测定
    蛋白质与肽
    按产品类型
    蛋白质组学工具
    激动剂、活化剂、拮抗剂与抑制剂
    细胞株和裂解液
    多重miRNA检测
    多因子分析试剂盒
    按研究领域
    癌症
    心血管
    细胞生物学
    表观遗传学
    代谢
    发育生物学
    按研究领域
    免疫学
    微生物学
    神经科学
    信号转导
    干细胞
  • 定制化产品 & 合作关系
    定制化产品 & 合作关系

    定制化产品和商务合作加速您的诊断和治疗项目

    定制化产品

    与我们成为伙伴

  • 技术支持
    支持中心

    获取研究建议和支持

    查看支持中心

    Protocols

    一步一步完成您的实验

    查看Protocols

  • 活动通知
    • 会议年历
    • 肿瘤研究
    • 心血管研究
    • 染色质及细胞核信号转导研究
    • 免疫学
    • 神经生物学
    • 干细胞研究
    • 商品展览
    • 实验技术视频
    查看最新活动

    活动说明、摘要提交、演讲者、注册方式及更多信息

    查看全球活动安排

  • 通路
    细胞信号转导通路

    查看所有通路

    查看交叉通路

Stem Cells Signaling Pathways Wnt Secreted

Anti-Wnt7a抗体(ab100792)

  • Datasheet
  • SDS
Reviews (2)Q&A (3)References (19)

Product price, shipping and contact information

Currently unavailable

抱歉,我们目前无法显示此内容。

请联系我们以完成下单,或者之后再尝试访问。

 

正在加载规格和价格。。。

 

送货和订单信息

运输费用

Promotion Information

Abpromise

产品质量保证,客户专家支持,

点击获取更多

Western blot - Anti-Wnt7a antibody (ab100792)
  • Western blot - Anti-Wnt7a antibody (ab100792)
  • Immunocytochemistry/ Immunofluorescence - Anti-Wnt7a antibody (ab100792)

Key features and details

  • Rabbit polyclonal to Wnt7a
  • Suitable for: WB, ICC/IF
  • Reacts with: Mouse, Human
  • Isotype: IgG

选择批间可重复性更高的重组抗体

Product image
Anti-Wnt7a antibody [EPR23471-125] (ab274321)
  • 研究可靠 —— 各批次间结果一致且可重复
  • 长期批量供应 —— 采用重组技术,可实现快速生产
  • 首次实验即可成功 —— 经过大量验证确认了特异性
  • 符合伦理标准 —— 产品不含动物成分

概述

  • 产品名称

    Anti-Wnt7a抗体
    参阅全部 Wnt7a 一抗
  • 描述

    兔多克隆抗体to Wnt7a
  • 宿主

    Rabbit
  • 经测试应用

    适用于: WB, ICC/IFmore details
  • 种属反应性

    与反应: Mouse, Human
    预测可用于: Chicken, Chimpanzee, Gorilla, Orangutan
  • 免疫原

    Synthetic peptide. This information is proprietary to Abcam and/or its suppliers.

  • 阳性对照

    • Recombinant human Wnt7a protein (ab116171) can be used as positive control in WB. In Western Blot, ab100792 gave a positive signal in Human kidney tissue lysate, human and mouse kidney lysate, HEPg2 cells, COLO 205 whole cell lysate and human colon tumor tissue. This antibody gave a positive result in ICC in HepG2 cells.
  • 常规说明

    The Life Science industry has been in the grips of a reproducibility crisis for a number of years. Abcam is leading the way in addressing this with our range of recombinant monoclonal antibodies and knockout edited cell lines for gold-standard validation. Please check that this product meets your needs before purchasing.

    If you have any questions, special requirements or concerns, please send us an inquiry and/or contact our Support team ahead of purchase. Recommended alternatives for this product can be found below, along with publications, customer reviews and Q&As

性能

  • 形式

    Liquid
  • 存放说明

    Shipped at 4°C. Store at +4°C short term (1-2 weeks). Upon delivery aliquot. Store at -20°C or -80°C. Avoid freeze / thaw cycle.
  • 存储溶液

    pH: 7.40
    Preservative: 0.02% Sodium azide
    Constituent: PBS

    Batches of this product that have a concentration < 1mg/ml may have BSA added as a stabilising agent. If you would like information about the formulation of a specific lot, please contact our scientific support team who will be happy to help.
  • Concentration information loading...
  • 纯度

    Immunogen affinity purified
  • 克隆

    多克隆
  • 同种型

    IgG
  • 研究领域

    • Stem Cells
    • Signaling Pathways
    • Wnt
    • Secreted
    • Cancer
    • Signal transduction
    • Other

相关产品

  • Compatible Secondaries

    • Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) (ab150077)
    • Goat Anti-Rabbit IgG H&L (HRP) (ab205718)
  • Isotype control

    • Rabbit IgG, polyclonal - Isotype Control (ChIP Grade) (ab171870)
  • Positive Controls

    • Recombinant human Wnt7a protein (ab116171)
  • Recombinant Protein

    • Recombinant human Wnt7a protein (ab116171)

应用

The Abpromise guarantee

Abpromise™承诺保证使用ab100792于以下的经测试应用

“应用说明”部分 下显示的仅为推荐的起始稀释度;实际最佳的稀释度/浓度应由使用者检定。

应用 Ab评论 说明
WB (1)
Use a concentration of 1 µg/ml. Detects a band of approximately 41 kDa (predicted molecular weight: 39 kDa).

Abcam recommends using 5% BSA as the blocking agent.

ICC/IF (1)
Use a concentration of 5 µg/ml.
说明
WB
Use a concentration of 1 µg/ml. Detects a band of approximately 41 kDa (predicted molecular weight: 39 kDa).

Abcam recommends using 5% BSA as the blocking agent.

ICC/IF
Use a concentration of 5 µg/ml.

靶标

  • 功能

    Ligand for members of the frizzled family of seven transmembrane receptors. Probable developmental protein. Signaling by Wnt-7a allows sexually dimorphic development of the mullerian ducts.
  • 组织特异性

    Expression is restricted to placenta, kidney, testis, uterus, fetal lung, and fetal and adult brain.
  • 疾病相关

    Defects in WNT7A are the cause of limb/pelvis-hypoplasia/aplasia syndrome (LPHAS) [MIM:276820]; also known as absence of ulna and fibula with severe limb deficiency. LPHAS is a limb-malformation disorder characterized by various degrees of limb aplasia/hypoplasia and joint dysplasia.
    Defects in WNT7A are a cause of Fuhrmann syndrome (FUHRS) [MIM:228930]; also known as fibular aplasia or hypoplasia femoral bowing and poly- syn- and oligodactyly. Fuhrmann syndrome is a distinct limb-malformation disorder characterized also by various degrees of limb aplasia/hypoplasia and joint dysplasia.
  • 序列相似性

    Belongs to the Wnt family.
  • 细胞定位

    Secreted > extracellular space > extracellular matrix.
  • Target information above from: UniProt accession O00755 The UniProt Consortium
    The Universal Protein Resource (UniProt) in 2010
    Nucleic Acids Res. 38:D142-D148 (2010) .

    Information by UniProt
  • 数据库链接

    • Entrez Gene: 749914 Chimpanzee
    • Entrez Gene: 101146237 Gorilla
    • Entrez Gene: 7476 Human
    • Entrez Gene: 22421 Mouse
    • Omim: 601570 Human
    • SwissProt: Q1KYL1 Chimpanzee
    • SwissProt: Q1KYK7 Gorilla
    • SwissProt: O00755 Human
    • SwissProt: P24383 Mouse
    • SwissProt: Q1KYK5 Orangutan
    • Unigene: 72290 Human
    • Unigene: 56964 Mouse
    see all
  • 别名

    • Protein Wnt-7a antibody
    • Protein Wnt-7a precursor antibody
    • Proto oncogene Wnt7a protein antibody
    • proto-oncogene wnt7a protein antibody
    • wingless-type MMTV integration site family, member 7A antibody
    • Wnt family member 7A antibody
    • WNT7A antibody
    • WNT7A_HUMAN antibody
    see all

图片

  • Western blot - Anti-Wnt7a antibody (ab100792)
    Western blot - Anti-Wnt7a antibody (ab100792)
    All lanes : Anti-Wnt7a antibody (ab100792) at 1 µg/ml

    Lane 1 : Human Kidney lysate
    Lane 2 : Mouse Kidney lysate
    Lane 3 : HepG2 whole cell lysate
    Lane 4 : COLO 205 whole cell lysate
    Lane 5 : Human Colon tumour tissue lysate

    Lysates/proteins at 10 µg per lane.

    Secondary
    All lanes : Goat Anti-Rabbit IgG H&L (HRP) at 1/50000 dilution

    Predicted band size: 39 kDa



    Exposure: 4 minutes

    Blocking buffer: 2% BSA

    Gel type: MOPS

    Observed band size: 41 kDa

    Additional bands: 50 kDa, 27kDa

  • Western blot - Anti-Wnt7a antibody (ab100792)
    Western blot - Anti-Wnt7a antibody (ab100792)
    Anti-Wnt7a antibody (ab100792) at 1 µg/ml + Human kidney tissue lysate - total protein (ab30203) at 10 µg

    Secondary
    Goat Anti-Rabbit IgG H&L (HRP) preadsorbed (ab97080) at 1/5000 dilution

    Developed using the ECL technique.

    Performed under reducing conditions.

    Predicted band size: 39 kDa
    Observed band size: 41 kDa why is the actual band size different from the predicted?
    Additional bands at: 15 kDa, 28 kDa. We are unsure as to the identity of these extra bands.


    Exposure time: 16 minutes
  • Immunocytochemistry/ Immunofluorescence - Anti-Wnt7a antibody (ab100792)
    Immunocytochemistry/ Immunofluorescence - Anti-Wnt7a antibody (ab100792)
    ICC/IF image of ab100792 stained HepG2 cells. The cells were 4% PFA fixed (10 min) and then incubated in 1%BSA / 10% normal goat serum / 0.3M glycine in 0.1% PBS-Tween for 1h to permeabilise the cells and block non-specific protein-protein interactions. The cells were then incubated with the antibody (ab100792, 5µg/ml) overnight at +4°C. The secondary antibody (green) was ab96899, DyLight® 488 goat anti-rabbit IgG (H+L) used at a 1/250 dilution for 1h. Alexa Fluor® 594 WGA was used to label plasma membranes (red) at a 1/200 dilution for 1h. DAPI was used to stain the cell nuclei (blue) at a concentration of 1.43µM. This antibody also gave a positive result in 4% PFA fixed (10 min) HeLa, Hek293 and MCF7 cells at 5µg/ml, and in 100% methanol fixed (5 min) HepG2 and MCF7 cells at 5µg/ml.

实验方案

  • Western blot protocols
  • Immunocytochemistry & immunofluorescence protocols

Click here to view the general protocols

数据表及文件

  • SDS download

  • Datasheet download

    Download

文献 (19)

发表研究结果有使用 ab100792?请让我们知道,以便我们可以引用本数据表中的参考文章。

ab100792 被引用在 19 文献中.

  • Yang L  et al. Wnt7a promotes the osteogenic differentiation of human mesenchymal stem cells. Int J Mol Med 47:N/A (2021). PubMed: 33846764
  • Zhang R  et al. lncRNA BCAR4 sponges miR-370-3p to promote bladder cancer progression via Wnt signaling. Int J Mol Med 45:578-588 (2020). PubMed: 31894304
  • Taxier LR  et al. Dickkopf-1 blocks 17ß-estradiol-enhanced object memory consolidation in ovariectomized female mice. Horm Behav 114:104545 (2019). PubMed: 31228421
  • Wang L  et al. miR-127 suppresses gastric cancer cell migration and invasion via targeting Wnt7a. Oncol Lett 17:3219-3226 (2019). PubMed: 30867752
  • Vallon M  et al. A RECK-WNT7 Receptor-Ligand Interaction Enables Isoform-Specific Regulation of Wnt Bioavailability. Cell Rep 25:339-349.e9 (2018). PubMed: 30304675
View all Publications for this product

客户评价及客户问答

Show All 评价 Q&A
提交评价 提交问题

1-5 of 5 Abreviews or Q&A

Immunocytochemistry/ Immunofluorescence abreview for Anti-Wnt7a antibody

Poor
Abreviews
Abreviews
Application
Immunocytochemistry/ Immunofluorescence
Sample
Mouse Cell (Brain)
Permeabilization
Yes - 0.5% with Triton X 100
Specification
Brain
Blocking step
Serum as blocking agent for 1 hour(s) and 0 minute(s) · Concentration: 10% · Temperature: 25°C
Fixative
Formaldehyde
Read More
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

Gulnaz Begum

Verified customer

提交于 Oct 31 2017

Western blot abreview for Anti-Wnt7a antibody

Average
Abreviews
Abreviews
abreview image
Application
Western blot
Sample
Mouse Cell lysate - whole cell (C2C12)
Gel Running Conditions
Reduced Denaturing (10% GEL)
Loading amount
30 µg
Specification
C2C12
Blocking step
Milk as blocking agent for 2 hour(s) and 0 minute(s) · Concentration: 5% · Temperature: 25°C
Read More
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

Abcam user community

Verified customer

提交于 Apr 15 2016

Question

Dear
Thanks for your kindly reply, after contacting with this customer and passed these suggestions to him, then he modified his experiment step as your suggestion, but it didn’t improve his results, he also indicated he didn’t has any positive control can test in this experiment, and he said the band which at 48kDa will disappear after he reused this antibody, he offered the RT-PCR data to prove this protein will expression in this sample, please check it and help this customer to solve the problem.
Thanks for your kindly help

Best regards

Read More

Abcam community

Verified customer

Asked on Mar 27 2012

Answer

Thank you for your reply.

I contacted with my lab colleagues who confirmed this lot has successfully passed our QC controls, and as with previous batches, it should be detecting a band at ˜40KDa, rather than 48KDa.

Please find attached one of the last blots obtained comparing our new batch (lane 1) with the batch you have tested (lane 3).

As you have mentioned, the band at ˜48KDa disappear when retesting the antibody, it may well be a non specific band. However, attending to the image sent on your first email, there is a weak band showing at ˜43 kDa that could be reduced by the milk blocking. I would therefore recommend you to use the same blocking agent used in our lab: 5%BSA, in an attempt to increase the target’s band intensity.

In any case, all of our products are covered by our Abpromise guarantee; which ensures that you can trust our products, and they should work in the tested species and applications stated on the datasheet, or we will offer a replacement, credit, or refund, if reported within 4 months of purchase.

To read about our Abpromise policy: https://www.abcam.com/index.html?pageconfig=abpromise

I hope these tips help, thank you for your cooperation. Should the suggestions not improve the results, please do not hesitate to contact me again and I’ll be more than happy to help you further.

Read More

Abcam Scientific Support

回复于 Mar 27 2012

Question

Dear technical support team:
This customer has purchased ab100792 (Anti-Wnt7a antibody) and has conducted the wb several times with human sample. The results show two bands, therefore, he would like to ask for your help to determine which the major band is, and could you please offer any suggestion to help him?
I also attached his image in this letter and his experiment step as follow:
1. Order details:
Abcam product code: ab100792
Batch number: XXXXXX
Po: XXXXXXX
Antibody storage conditions (temperature/reconstitution etc) -20°C
2. Please describe the problem (high background, wrong band size, more bands, no band etc). Two bands
3. On what material are you testing the antibody in WB?
· Species:
· What’s cell line or tissue: Lung cancer cell line
· Cell extract or Nuclear extract: whole cell lysate
· Purified protein or Recombinant protein:
3. The lysate
How much protein was loaded: 40ug
What lysis buffer was used:
What protease inhibitors were used: protein inhibitor set III, Roche inhibitor
What loading buffer was used: 2X Laemmli buffer
Phosphatase inhibitors
· Did you heat the samples: temperature and time: 100℃ 5min
4. Electrophoresis/Gel conditions/ Transfer conditions
Reducing or non reducing gel:
Reducing agent:
Gel percentage :
Transfer conditions: (Type of membrane, Protein transfer verified):
5. Blocking conditions
Buffer: TBS
Blocking agent: milk, BSA, serum, what percentage: 3% milk
Incubation time: 2h
Incubation temperature: RT
6. Primary Antibody
Species:
Reacts against:
· At what dilution(s) have you tested this antibody: 1:1500
· What dilution buffer was used: 3% milk in TBS
· Incubation time: overnight
· Incubation temperature: 4℃
· What washing steps were done: 3 times
7. Secondary Antibody
Species:
Reacts against:
At what dilution(s) have you tested this antibody: 1:3000
Incubation time: 2 h
Wash steps: Blocking buffer wash 3 time
Fluorochrome or enzyme conjugate:
Do you know whether the problems you are experiencing come from the secondary? no
8. Detection method
ECl, ECl+, other detection method:ECl
9. Did you apply positive and negative controls along with the samples? Please specify.
10. Optimization attempts
· How many times have you tried the Western? 5
· Have you eliminated the possibility that any background bands could be due to the secondary antibody? (Run a “No primary” control): no
· Do you obtain the same results every time e.g. are background bands always in the same place? yes
· What steps have you altered?
Could you please help this customer to solve the problem?Thanks for your kindly help

Read More

Abcam community

Verified customer

Asked on Mar 23 2012

Answer

Thank you for taking the time to complete our questionnaire.

The predicted band size for this protein is 39KDa, however, attending at our in-house tests, the observed band size appears at approximately 41KDa, and other unknown additional bands are shown at lower molecular weights.

In order to identify the correct band for the protein I would suggest using a positive control. Human kidney tissue lysate has been proved to express this protein, and therefore could be used as such.

In an attempt to improve the results observed I would suggest increasing the percentage of milk to 5% as well as optimising the sample preparation lysing your tissue with RIPA buffer and adding phosphatase inhibitors.

I would also recommend decreasing the protein load to 20ug, and using less concentrate dilution of primary antibody (e.g. 1/1000).

I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

Read More

Abcam Scientific Support

回复于 Mar 23 2012

Question

These are the translated AA seq's I'm working with let me know what you can find out. DVL1 Pig aa seq K G G A V A A D G R T E P G D Met L L Q V N D V N F E N Met S N D D A V R V L R E I V S Q T G P I S L T V A K C W D P S P R S Y F T I P R A D P V R P I D P A A W L S H T A A L T G A L P R Y G T S P C S S A V T R T S S S S L T S S V P G A P Q L E E A P L T V K S D Met G A V V R V Met Q L P D S G L E I R D R Met W L K I T I A N A V I G A D V V D W L Y T H L E G F R E R R E A R R Y A S S Met L K R G F L R H T V N K V T F S E Q C Y Y V F G D L C S N L A A L N L N S G S S G A S D Q D T L A P L P H P A A P W P L G Q G Y P Y Q Y P G P P P C F P P A Y Q D P G F S Y G S G S A G S Q Q S E G S K S S G S T R S A G G S S R R A L G R E K E S R S A G A G G S G S E S D H T A P S G A G G S G W R E R P A S Q L S R G S S P R S Q A S A A A P G L P P L H P L T K A Y S V V G G P P G G P P V R E L A A V P P E L T G S R Q S F Q K A Met G N P C E F F V D I Met wnt7a pig aa seq N L H N N E A G R K I L E E N Met K L E C K C H G V S G S C T T K T C W T T L P Q F R E L G Y V L K D K Y N E A V H V E P V R A S R N K R P T F L K I K K P L S Y R K P Met D T D L V Y I E K S P N Y C E E D P V T G S V G T Q G R A C N K T A P Q A S G C D L Met C C G R G Y N T H Q Y A R V W Q C N C K F H W C C Y V K C N T C S E R T E V Y T C K

Read More

Abcam community

Verified customer

Asked on Oct 28 2011

Answer

Thank you for calling Abcam. I have done the alignment between the sequences you sent and the immunogen sequences for the antibodies we discussed. For DVL1, there is 75% match between the sequence you sent and the immunogen sequence used for ab106914. We normally look for a 85% similarity before we would recommended trying an antibody, so in this case I do not think the antibody will react with pig. For Wtn7a, there is a 100% match between your sequence and the immunogen sequence used for ab100792. Therefore I would be very confident that this antibody would recognize pig Wnt7a. Please let me know if there is anything else I can help you with.

Read More

Abcam Scientific Support

回复于 Oct 28 2011

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

通过邮件收到学术资源和促销信息 注册
研究类别(A-Z)
  • 肿瘤研究
  • 心血管研究
  • 细胞生物学
  • 发育生物学
  • 染色质及细胞核信号转导研究
  • 免疫学
  • 代谢
  • 微生物学
  • 神经生物学
  • 信号转导研究
  • 干细胞研究
产品种类(A-Z)
  • 一抗
  • 二抗
  • 生化试剂
  • 亚类对照
  • 流式细胞仪多色选择器
  • 试剂盒
  • 内参对照
  • 细胞裂解液
  • 多肽
  • 蛋白酶
  • 组织切片
  • 蛋白标签及细胞标记物
  • 相关试剂及工具
帮助与支持
  • 技术支持
  • 技术FAQ
  • 实验步骤与建议
  • 购买FAQ
  • RabMAb 产品
  • 培训课程
  • 按靶标浏览
企业
  • 企业资讯
  • 投资者关系
  • 公司新闻
  • 招贤纳士
  • 关于我们
活动通知
  • 商品展览
  • 会议
全球网站
  • abcam.com
  • abcam.co.jp
QR code for Weechat

微信扫码 关注我们

沪ICP备14046373号-1

沪公网安备 31011502007413号

  • 销售条款
  • 网站使用条款
  • Cookie政策
  • 隐私权政策
  • 法律
© 1998-2023 艾博抗(上海)贸易有限公司版权所有