Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control
Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control
- BOND RX™ Validated
- Recombinant
- 了解详情
Be the first to review this product! Submit a review
|
(4 Publications)
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (AB280974)
Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% Triton X-100 permeabilized RAW 264.7 cells labelling Mouse IgG1 with ab280974 at 1/20 dilution, followed by ab150113 Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) antibody at 1/1000 dilution (Green). ab179513 Anti-beta Tubulin rabbit monoclonal antibody was used to counterstain tubulin at 1/200 dilution followed by ab150080 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 594) at 1/1000 dilution (Red). The nuclear counterstain was DAPI (Blue).
Confocal image showing no staining in RAW 264.7 cells.
Negative control 1 : ab280974 at a 1/20 dilution followed by ab150080 at a 1/1000 dilution.
Negative control 2 : ab179513 at a 1/200 dilution followed by ab150113 at a 1/1000 dilution.
- Flow Cyt (Intra)
Supplier Data
Flow Cytometry (Intracellular) - Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (AB280974)
Flow cytometric analysis of 4% paraformaldehyde fixed 90% methanol permeabilized HeLa (Human cervix adenocarcinoma epithelial cell) cells labelling Mouse IgG1 with ab280974 at 1/500 dilution (0.1μg) (Red) compared with a Mouse IgG1, kappa monoclonal [MOPC-21] - isotype control ab18443 (Black) and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue). A Goat anti mouse IgG (Alexa Fluor® 488, ab150113) at 1/2000 dilution was used as the secondary antibody.
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (AB280974)
Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% Triton X-100 permeabilized HeLa cells labelling Mouse IgG1 with ab280974 at 1/20 dilution, followed by ab150113 Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) antibody at 1/1000 dilution (Green). ab179513 Anti-beta Tubulin rabbit monoclonal antibody was used to counterstain tubulin at 1/200 dilution followed by ab150080 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 594) at 1/1000 dilution (Red). The nuclear counterstain was DAPI (Blue).
Confocal image showing no staining in HeLa cells.
Negative control 1 : ab280974 at a 1/20 dilution followed by ab150113 at a 1/1000 dilution.
Negative control 2 : ab179513 at a 1/200 dilution followed by ab150080 at a 1/1000 dilution.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (AB280974)
Immunohistochemical analysis of paraffin-embedded mouse kidney tissue labeling Mouse IgG1 with ab280974 at 1/100 dilution followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection). The section was incubated with ab280974 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
No staining on the mouse kidney.
Secondary antibody only control : Secondary antibody is ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (AB280974)
Immunohistochemical analysis of paraffin-embedded rat kidney tissue labeling Mouse IgG1 with ab280974 at 1/100 dilution followed by ready to use LeicaDS9800 (Bond™ Polymer Refine Detection). The section was incubated with ab280974 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
No staining on the rat kidney.
Secondary antibody only control : Secondary antibody is ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (AB280974)
Immunohistochemical analysis of paraffin-embedded human colon tissue labeling Mouse IgG1 with ab280974 at 1/100 dilution followed by ready to use LeicaDS9800 (Bond™ Polymer Refine Detection). The section was incubated with ab280974 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
No staining on the human colon.
Secondary antibody only control : Secondary antibody is ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
- Flow Cyt (Intra)
Supplier Data
Flow Cytometry (Intracellular) - Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (AB280974)
Flow cytometric analysis of 4% paraformaldehyde fixed 90% methanol permeabilized RAW 264.7 (Human cervix adenocarcinoma epithelial cell, Left) / PC-12 (Rat adrenal gland pheochromocytoma, Right) cells labelling Mouse IgG1 with ab280974 at 1/500 dilution (0.1μg) (Red) compared with a Mouse IgG1, kappa monoclonal [MOPC-21] - isotype control ab18443 (Black) and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue). A Goat anti mouse IgG (Alexa Fluor® 488, ab150113) at 1/2000 dilution was used as the secondary antibody.
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (AB280974)
Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% Triton X-100 permeabilized PC-12 cells labelling Mouse IgG1 with ab280974 at 1/20 dilution, followed by ab150113 Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) antibody at 1/1000 dilution (Green). ab179513 Anti-beta Tubulin rabbit monoclonal antibody was used to counterstain tubulin at 1/200 dilution followed by ab150080 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 594) at 1/1000 dilution (Red). The nuclear counterstain was DAPI (Blue).
Confocal image showing no staining in PC-12 cells.
Negative control 1 : ab280974 at a 1/20 dilution followed by ab150080 at a 1/1000 dilution.
Negative control 2 : ab179513 at a 1/200 dilution followed by ab150113 at a 1/1000 dilution.
反应性数据
产品详情
What is this antibody validated in?
Mouse IgG1 monoclonal [R312-MouseIgG1]-Isotype control (ab280974) is a mouse recombinant monoclonal antibody and is validated for use in Flow Cytometry (Intra), Flow Cytometry (Flow Cyt), Immunohistochemistry (IHC-P), Immunocytochemistry/immunofluorescence (ICC/IF). Other related products
We have a range of other formats of antibody clone [R312-MouseIgG1] also available for your convenience: ab280974, Carrier free - ab281291, FITC - ab314952, PE - ab322670
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
性能和储存信息
形式
纯化工艺
存储溶液
运输条件
推荐的短期储存时间
推荐的短期储存条件
推荐的长期储存条件
分装信息
储存信息
产品实验方案
- Visit the General protocols
- Visit the Troubleshooting
靶点信息
文献 (4)
Recent publications for all applications. Explore the full list and refine your search
PLoS pathogens 20:e1012725 PubMed39585899
2024
Applications
Unspecified application
Species
Unspecified reactive species
JCI insight 8: PubMed37471168
2023
Applications
Unspecified application
Species
Unspecified reactive species
Aging and disease 14:484-501 PubMed37008056
2023
Applications
Unspecified application
Species
Unspecified reactive species
British journal of cancer 128:1466-1477 PubMed36759726
2023
Applications
Unspecified application
Species
Unspecified reactive species
Abcam Product Promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com