Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent
Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent
- SimpleStep
- 了解详情
Be the first to review this product! Submit a review
|
(0 Publication)
Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent is a 55-min single-wash Simplestep IgniteTM ELISA for the rapid quantification of Human Pro-Collagen I alpha 1 with higher sensitivity and broader measuring range.
- Single 30 min incubation and single -wash step for results in less than an hour
- Chemiluminescent detection allows a broad dynamic range :4.57 - 10000 pg/mL with a sensitivity of 3.2 pg/mL
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
- Patent Pending
查看别名
Collagen alpha-1(I) chain, Alpha-1 type I collagen, COL1A1
- sELISA
Lab
Sandwich ELISA - Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent (AB325360)
SimpleStep ELISA® Ignite technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 55 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
- sELISA
Lab
Sandwich ELISA - Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent (AB325360)
Serum of ten individual healthy human female donors was measured in duplicate. Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Pro-Collagen I alpha 1 concentration was determined to be 227.8 ng/mL with a range of 118.4 – 368.9 ng/mL.
- sELISA
Lab
Sandwich ELISA - Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent (AB325360)
Standard curve comparison between the Chemiluminescent Human Pro-Collagen I alpha 1 SimpleStep ELISA and colorimetric Human Pro-Collagen I alpha 1 SimpleStep ELISA (ab210966) in Sample Diluent NS. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Lab
Sandwich ELISA - Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent (AB325360)
Interpolated concentration of native Pro-Collagen I alpha 1 was measured in duplicate at different sample concentrations. Undiluted samples are as follows : 50% human urine and 10% human saliva. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions are made in Sample Diluent NS.
- sELISA
Lab
Sandwich ELISA - Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent (AB325360)
Interpolated concentration of native Pro-Collagen I alpha 1 was measured in duplicate at different sample concentrations. Undiluted samples are 2 µg/mL IMR-90 cell extract. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). Sample dilutions are made in 1X Cell Extraction Buffer PTR.
- sELISA
Lab
Sandwich ELISA - Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent (AB325360)
Standard curve comparison between the Chemiluminescent Human Pro-Collagen I alpha 1 SimpleStep ELISA and colorimetric Human Pro-Collagen I alpha 1 SimpleStep ELISA (ab210966) in 1X Cell Extraction Buffer PTR. Background-subtracted data values (mean +/- SD) are graphed.
反应性数据
产品详情
Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent (ab325360) is a rapid single-wash sandwich 55-min ELISA to measure Human Pro-Collagen I alpha 1 in Serum, Citrate Plasma, EDTA Plasma, Heparin Plasma, Cell Culture Media, Urine, Saliva, Cell Extract with a sensitivity of 3.2 pg/ml.
How the assay works
Human Pro-Collagen I alpha 1 ELISA Kit, Chemiluminescent (ab325360) SimpleStep ELISA® employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step during a 30 min only incubation, significantly reducing assay time. By utilizing a chemiluminscent detection method this improves the sensitivity and dynamic range when compared to traditional colorimetric ELISAs.
Assay Specificity
Our SimpleStep ELISA® kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Human Pro-Collagen I alpha 1 (ab325360) protocol summary
1. Mix : add samples / standards to the wells together with the capture and detector antibody cocktail. Incubate 30 min at room temperature
2. Wash
3. Add prepared ChemiHRP development solution - incubate for 2 min
4. Read the results on a plate reader capable of luminescence detection
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation:
- Rabbit monoclonal [EPR19126-161] to P1NP - BSA and Azide free (Capture) ab242540
- Rabbit monoclonal [EPR19126-152] to P1NP - BSA and Azide free (Detector) ab242788
REACH authorisation
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
精确度
回收率
规格
性能和储存信息
运输条件
推荐的短期储存条件
推荐的长期储存条件
储存信息
靶点信息
Abcam Product Promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com