JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB325369

Human Albumin ELISA Kit, Chemiluminescent

Human Albumin ELISA Kit, Chemiluminescent

Be the first to review this product! Submit a review

|

(0 Publication)

Human Albumin ELISA Kit, Chemiluminescent is a 55-min single-wash Simplestep IgniteTM ELISA for the rapid quantification of Human Albumin with higher sensitivity and broader measuring range.

- Single 30 min incubation and single -wash step for results in less than an hour
- Chemiluminescent detection allows a broad dynamic range :0.045 - 100 pg/mL with a sensitivity of 5 pg/mL
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
- Patent Pending

查看别名

GIG20, GIG42, PRO0903, PRO1708, PRO2044, PRO2619, PRO2675, UNQ696/PRO1341, ALB, Albumin

5 Images
Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)
  • sELISA

Lab

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)

SimpleStep ELISA® Ignite technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 55 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)
  • sELISA

Lab

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)

Serum of eight individual healthy human female donors was measured in duplicate. Interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). The mean Albumin concentration was determined to be 23.4 mg/mL with a range of 10.5 – 37.1 mg/mL.

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)
  • sELISA

Lab

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)

Dynamic range comparison between the Chemiluminescent Human Albumin SimpleStep ELISA, colorimetric Human Albumin SimpleStep ELISA (ab179887). The Chemiluminescent SimpleStep ELISA kit shows increased sensitivity and increased dynamic range.

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)
  • sELISA

Lab

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)

The concentrations of Albumin were measured in duplicates, interpolated from the Albumin standard curves and corrected for sample dilution. Undiluted samples are as follows : serum 1 : 4,000,000, plasma (EDTA) 1 : 4,000,000, plasma (citrate) 1 : 8,000,000, and plasma (heparin) 1 : 8,000,000. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions are made in Sample Diluent NS.

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)
  • sELISA

Lab

Sandwich ELISA - Human Albumin ELISA Kit, Chemiluminescent (AB325369)

Standard curve comparison between the Chemiluminescent Human Albumin SimpleStep ELISA and colorimetric Human Albumin SimpleStep ELISA (ab179887) in Sample Diluent NS. Background-subtracted data values (mean +/- SD) are graphed.

关键信息

检测方法

Luminescent

样品类型

Serum, Citrate plasma, EDTA Plasma, Heparin Plasma, Cell culture media

反应种属

Human

检测类型

Sandwich (quantitative)

灵敏度

= 5 pg/mL

范围

0.0457 - 100 ng/mL

检测时间

55m

检测平台

Pre-coated microplate (12 x 8 well strips)

反应性数据

{ "title": "Reactivity Data", "filters": { "stats": ["", "Reactivity", "Dilution Info", "Notes"] }, "values": { "sELISA": { "reactivity":"TESTED_AND_REACTS", "dilution-info":"", "notes":"<p></p>" } } }

产品详情

Human Albumin ELISA Kit, Chemiluminescent (ab325369) is a rapid single-wash sandwich 55-min ELISA to measure Human Albumin in Serum, Citrate Plasma, EDTA Plasma, Heparin Plasma, Cell Culture Media with a sensitivity of 5 pg/ml.

How the assay works

Human Albumin ELISA Kit, Chemiluminescent (ab325369) SimpleStep ELISA®  employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step during a 30 min only incubation, significantly reducing assay time.  By utilizing a chemiluminscent detection method this improves the sensitivity and dynamic range when compared to traditional colormetric ELISAs.

Assay Specificity

Our SimpleStep ELISA® kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.

Please refer to our protocol booklet for more details.

Human Albumin (ab325369) protocol summary

1. Mix : add samples / standards to the wells together with the capture and detector antibody cocktail. Incubate 30 min at room temperature

2. Wash

3. Add prepared ChemiHRP development solution - incubate for 2 min

4. Read the results on a plate reader capable of luminescence detection

Design your own immunoassay

We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation:

- Rabbit monoclonal [EPR20195-105] to Human Serum Albumin - BSA and Azide free (Capture) ab244696

- Rabbit monoclonal [EPR20195-16] to Human Serum Albumin - BSA and Azide free (Detector) ab244962

精确度

[ { "reproducibilityType": "Intra", "sample": "Serum", "replicates": 8, "mean": null, "standardDeviation": null, "coefficientOfVariability": "5.2" }, { "reproducibilityType": "Inter", "sample": "Serum", "replicates": 3, "mean": null, "standardDeviation": null, "coefficientOfVariability": "7.6" } ]

回收率

[ { "sample": "Serum", "range": "92 - 110 %", "average": "= 100" }, { "sample": "Citrate plasma", "range": "100 - 103 %", "average": "= 101" }, { "sample": "EDTA Plasma", "range": "97 - 109 %", "average": "= 104" }, { "sample": "Heparin Plasma", "range": "89 - 105 %", "average": "= 98" }, { "sample": "Cell culture media", "range": "104 - 105 %", "average": "= 104" } ]

规格

{ "values": { "1x96Tests": { "sellingSize": "1 x 96 Tests", "publicAssetCode":"ab325369-1x96Tests", "assetComponentDetails": [ { "size":"1 x 3 mL", "name":"ChemiHRP Reagent A", "number":"AB325369-CMP07", "productcode":"" }, { "size":"1 x 1 Unit", "name":"SimpleStep Pre-Coated Black 96-Well Microplate", "number":"AB325369-CMP09", "productcode":"" }, { "size":"2 x 1 Vial", "name":"Human Albumin Lyophilized Purified Protein", "number":"AB325369-CMP03", "productcode":"" }, { "size":"1 x 1 Unit", "name":"Plate Seal", "number":"AB325369-CMP10", "productcode":"" }, { "size":"1 x 3 mL", "name":"ChemiHRP Reagent B", "number":"AB325369-CMP08", "productcode":"" }, { "size":"2 x 50 mL", "name":"Sample Diluent NS (ab193972)", "number":"AB325369-CMP06", "productcode":"" }, { "size":"1 x 6 mL", "name":"Antibody Diluent 4BI", "number":"AB325369-CMP04", "productcode":"" }, { "size":"1 x 600 µL", "name":"10X Human Albumin Detector Antibody", "number":"AB325369-CMP02", "productcode":"" }, { "size":"1 x 600 µL", "name":"10X Human Albumin Capture Antibody", "number":"AB325369-CMP01", "productcode":"" }, { "size":"1 x 20 mL", "name":"10X Wash Buffer PT (ab206977)", "number":"AB325369-CMP05", "productcode":"" } ] } } }

性能和储存信息

运输条件
Blue Ice
推荐的短期储存条件
+4°C
推荐的长期储存条件
+4°C
储存信息
+4°C

产品实验方案

靶点信息

Binds water, Ca(2+), Na(+), K(+), fatty acids, hormones, bilirubin and drugs (Probable). Its main function is the regulation of the colloidal osmotic pressure of blood (Probable). Major zinc transporter in plasma, typically binds about 80% of all plasma zinc (PubMed : 19021548). Major calcium and magnesium transporter in plasma, binds approximately 45% of circulating calcium and magnesium in plasma (By similarity). Potentially has more than two calcium-binding sites and might additionally bind calcium in a non-specific manner (By similarity). The shared binding site between zinc and calcium at residue Asp-273 suggests a crosstalk between zinc and calcium transport in the blood (By similarity). The rank order of affinity is zinc > calcium > magnesium (By similarity). Binds to the bacterial siderophore enterobactin and inhibits enterobactin-mediated iron uptake of E.coli from ferric transferrin, and may thereby limit the utilization of iron and growth of enteric bacteria such as E.coli (PubMed : 6234017). Does not prevent iron uptake by the bacterial siderophore aerobactin (PubMed : 6234017).
See full target information ALB
websiteProtocolBooklet
en

Abcam Product Promise

我们致力于为您的研究提供高质量的试剂,为您科研的每一步提供支持。若我们的产品未能达到预期性能,我们向您提供 Abcam Product Promise 保障。
详情请参阅我们的条款与条件。

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com