Adenylate Cyclase Activity Assay
Adenylate Cyclase Activity Assay
Be the first to review this product! Submit a review
|
(0 Publication)
- FuncS
Supplier Data
Functional Studies - Adenylate Cyclase Activity Assay (AB323608)
Adenylate Cyclase Activity Assay Kit reaction pathway
- FuncS
Supplier Data
Functional Studies - Adenylate Cyclase Activity Assay (AB323608)
Example standard curve (0-10 nmol) used to determine the activity of adenylate cyclase. The change in absorbance over a time range for a sample is used to determine the nmol of PPi generated due to adenylate cyclase activity in a defined time frame. ΔAbsorbance must be within the range of the standard curve.
- FuncS
Supplier Data
Functional Studies - Adenylate Cyclase Activity Assay (AB323608)
Example midrange positive control data. The linear range for this positive control occurs between 5 and 18 minutes. Prior to five minutes, the reaction is coming to temperature and is experiencing a lag as the enzyme ramps up, after 18 minutes the substrate is becoming depleted and activity is slowing. Choosing a time interval within the linear range for each sample is critical to accurately quantify adenylate cyclase activity.
- Biochemical assay
Supplier Data
Biochemical assay - Adenylate Cyclase Activity Assay (AB323608)
Adenylate Cyclase activity in cell and tissue lysates. Samples were lysed according to the sample preparation protocol and 4 µl of each sample was tested. Specific activity was calculated from sample concentration determined using a Bradford assay.
反应性数据
产品详情
The Adenylate Cyclase Activity assay kit is a simple, sensitive kit that measures the conversion of ATP to cAMP and pyrophosphate using a propriety enzymatic detection mix and a chromogenic probe to generate a stable chromophore that can be quantified by absorbance.
In the first step of this enzymatic assay, Adenylyl Cyclase (Adenylate Cyclase) converts ATP into cAMP, releasing inorganic pyrophosphate (PPi). The PPi released is detected via a series of enzymatic reactions which utilize a propriety enzyme mix and a chromogenic probe, generating a stable chromophore that can be quantified by absorbance at 570 nm.
First functional test on catalogue, others are ELISA based and either only measure cAMP levels or AC protein concentration.
规格
性能和储存信息
运输条件
推荐的短期储存条件
推荐的长期储存条件
储存信息
Abcam Product Promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com