JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB197446

人IGF Signaling抗体阵列(10 Targets) - Quantitative

Human IGF Signaling Antibody Array (10 Targets) - Quantitative

Be the first to review this product! Submit a review

|

(1 Publication)

ab197446 can be used for quantitative measurement of 10 Human cytokines.

查看别名

IBP1, IGF-1, IGF1, Insulin-like growth factor 1, Insulin-like growth factor I, Mechano growth factor, Somatomedin-C, IGF-I, MGF, BP2, IBP2, IGFBP2, Insulin-like growth factor-binding protein 2, IBP-2, IGF-binding protein 2, IGFBP-2, CD221, Insulin-like growth factor 1 receptor, Insulin-like growth factor I receptor, IGF-I receptor, IGF1R, IBP4, IGFBP4, Insulin-like growth factor-binding protein 4, IBP-4, IGF-binding protein 4, IGFBP-4, Insulin, INS, IBP1, IGFBP1, Insulin-like growth factor-binding protein 1, IBP-1, IGF-binding protein 1, IGFBP-1, Placental protein 12, PP12, IBP3, IGFBP3, Insulin-like growth factor-binding protein 3, IBP-3, IGF-binding protein 3, IGFBP-3, IGF-2, PP1446, IGF2, Insulin-like growth factor 2, Insulin-like growth factor II, Somatomedin-A, T3M-11-derived growth factor, IGF-II, CD222, MPRI, IGF2R, Cation-independent mannose-6-phosphate receptor, CI Man-6-P receptor, CI-MPR, M6PR, 300 kDa mannose 6-phosphate receptor, Insulin-like growth factor 2 receptor, Insulin-like growth factor II receptor, M6P/IGF2 receptor, MPR 300, IGF-II receptor, M6P/IGF2R, IBP6, IGFBP6, Insulin-like growth factor-binding protein 6, IBP-6, IGF-binding protein 6, IGFBP-6

3 Images
Multiplex Protein Detection - Human IGF Signaling Antibody Array (10 Targets) - Quantitative (AB197446)
  • Multiplex Protein Detection

Supplier Data

Multiplex Protein Detection - Human IGF Signaling Antibody Array (10 Targets) - Quantitative (AB197446)

Array map for Abcam Human IGF Signaling Antibody Array (10 Targets) - Quantitative (ab197446).

Multiplex Protein Detection - Human IGF Signaling Antibody Array (10 Targets) - Quantitative (AB197446)
  • Multiplex Protein Detection

Supplier Data

Multiplex Protein Detection - Human IGF Signaling Antibody Array (10 Targets) - Quantitative (AB197446)

Standard curve obtained using Abcam Human IGF Signaling Antibody Array (10 Targets) - Quantitative (ab197446).

Multiplex Protein Detection - Human IGF Signaling Antibody Array (10 Targets) - Quantitative (AB197446)
  • Multiplex Protein Detection

Supplier Data

Multiplex Protein Detection - Human IGF Signaling Antibody Array (10 Targets) - Quantitative (AB197446)

Assay summary for Abcam Human IGF Signaling Antibody Array (10 Targets) - Quantitative (ab197446).

关键信息

反应种属

Human

靶标

IGF1

target

检测方法

Fluorescent

检测平台

Multiplex

样品类型

Tissue Lysate, Plasma, Cell culture media, Serum, Other biological fluids, Cell Lysate

产品详情

ab197446 can be used for quantitative measurement of 10 Human cytokines. Suitable for serum, plasma, cell culture media, other body fluids, cell and tissue lysates.

Targets names: IGF-1, IGF-2, Insulin, IGF-1R, IGF-2R, IGFBP-1, IGFBP-2, IGFBP-3, IGFBP-4, IGFBP-6.

Quantitative antibody arrays can be used to quantitate up to 40 cytokines with as little as 50 µL of sample. Arrays are available for 400 human and 200 mouse proteins. Each glass slide is spotted with 16 identical antibody arrays and is provided with a 16 well gasket to allow separate samples to be applied to each array. Each antibody is spotted in quadruplicate in each array. For reproducible quantitation, eight of the arrays are used with a cocktail of protein standards to produce a standard curve. The same 8 standard curve arrays can be used across multiple slides, allowing measurement of 22 experimental samples with 2 slides, 36 with 3 slides etc. For high through-put, 4 slides can be nested into a tray matching a standard microplate, allowing automated processing with a liquid handling workstation. Array processing can be completed within one working day (see workflow diagram below) and arrays can be analyzed with a wide number of laser glass slide array / gene microarray scanners. If you don’t have a suitable scanner then we recommend our membrane antibody arrays, which can be analyzed with any WB chemiluminescent reader. "

规格

{ "values": { "50Test": { "sellingSize": "50 Test", "publicAssetCode":"ab197446-50Test", "assetComponentDetails": [ { "size":"6 x 30 mL", "name":"20X Wash Buffer I", "number":"AB197446-CMP06" }, { "size":"2 x 30 mL", "name":"20X Wash Buffer II", "number":"AB197446-CMP07" }, { "size":"4 x 1 Slide", "name":"Human IGF Signaling Array (10 T) Glass Slide", "number":"AB197446-CMP04" }, { "size":"2 x 15 mL", "name":"Sample Diluent", "number":"AB197446-CMP01" }, { "size":"2 x 1 Unit", "name":"Slide Washer/Dryer (30 mL Centrifuge Tube)", "number":"AB197446-CMP02" }, { "size":"4 x 25 µL", "name":"Human IGF Signaling Array (10 T) Biotinylated Antibody Cocktail", "number":"AB197446-CMP03" }, { "size":"2 x 1 Vial", "name":"Human IGF Signaling Array (10 T) Lyophilized Cytokine Standard Mix", "number":"AB197446-CMP05" }, { "size":"4 x 5 µL", "name":"Cy3 equivalent dye-conjugated Streptavidin", "number":"AB197446-CMP08" }, { "size":"4 x 1 Unit", "name":"Adhesive Film", "number":"AB197446-CMP09" } ] }, "8Test": { "sellingSize": "8 Test", "publicAssetCode":"ab197446-8Test", "assetComponentDetails": [ { "size":"1 x 30 mL", "name":"20X Wash Buffer II", "number":"AB197446-CMP07" }, { "size":"1 x 15 mL", "name":"Sample Diluent", "number":"AB197446-CMP01" }, { "size":"2 x 30 mL", "name":"20X Wash Buffer I", "number":"AB197446-CMP06" }, { "size":"1 x 1 Slide", "name":"Human IGF Signaling Array (10 T) Glass Slide", "number":"AB197446-CMP04" }, { "size":"1 x 1 Unit", "name":"Slide Washer/Dryer (30 mL Centrifuge Tube)", "number":"AB197446-CMP02" }, { "size":"1 x 25 µL", "name":"Human IGF Signaling Array (10 T) Biotinylated Antibody Cocktail", "number":"AB197446-CMP03" }, { "size":"1 x 1 Vial", "name":"Human IGF Signaling Array (10 T) Lyophilized Cytokine Standard Mix", "number":"AB197446-CMP05" }, { "size":"1 x 5 µL", "name":"Cy3 equivalent dye-conjugated Streptavidin", "number":"AB197446-CMP08" }, { "size":"1 x 1 Unit", "name":"Adhesive Film", "number":"AB197446-CMP09" } ] }, "22Test": { "sellingSize": "22 Test", "publicAssetCode":"ab197446-22Test", "assetComponentDetails": [ { "size":"2 x 1 Unit", "name":"Adhesive Film", "number":"AB197446-CMP09", "productcode":"" }, { "size":"1 x 1 Unit", "name":"Slide Washer/Dryer (30 mL Centrifuge Tube)", "number":"AB197446-CMP02", "productcode":"" }, { "size":"1 x 30 mL", "name":"20X Wash Buffer II", "number":"AB197446-CMP07", "productcode":"" }, { "size":"1 x 15 mL", "name":"Sample Diluent", "number":"AB197446-CMP01", "productcode":"" }, { "size":"2 x 1 Slide", "name":"Human IGF Signaling Array (10 T) Glass Slide", "number":"AB197446-CMP04", "productcode":"" }, { "size":"3 x 30 mL", "name":"20X Wash Buffer I", "number":"AB197446-CMP06", "productcode":"" }, { "size":"1 x 1 Vial", "name":"Human IGF Signaling Array (10 T) Lyophilized Cytokine Standard Mix", "number":"AB197446-CMP05", "productcode":"" }, { "size":"2 x 25 µL", "name":"Human IGF Signaling Array (10 T) Biotinylated Antibody Cocktail", "number":"AB197446-CMP03", "productcode":"" }, { "size":"2 x 5 µL", "name":"Cy3 equivalent dye-conjugated Streptavidin", "number":"AB197446-CMP08", "productcode":"" } ] } } }

性能和储存信息

运输条件
Blue Ice
推荐的短期储存条件
-20°C
推荐的长期储存条件
-20°C
储存信息
-20°C

产品实验方案

靶点信息

The insulin-like growth factors, isolated from plasma, are structurally and functionally related to insulin but have a much higher growth-promoting activity. May be a physiological regulator of [1-14C]-2-deoxy-D-glucose (2DG) transport and glycogen synthesis in osteoblasts. Stimulates glucose transport in bone-derived osteoblastic (PyMS) cells and is effective at much lower concentrations than insulin, not only regarding glycogen and DNA synthesis but also with regard to enhancing glucose uptake. May play a role in synapse maturation (PubMed : 21076856, PubMed : 24132240). Ca(2+)-dependent exocytosis of IGF1 is required for sensory perception of smell in the olfactory bulb (By similarity). Acts as a ligand for IGF1R. Binds to the alpha subunit of IGF1R, leading to the activation of the intrinsic tyrosine kinase activity which autophosphorylates tyrosine residues in the beta subunit thus initiating a cascade of down-stream signaling events leading to activation of the PI3K-AKT/PKB and the Ras-MAPK pathways. Binds to integrins ITGAV : ITGB3 and ITGA6 : ITGB4. Its binding to integrins and subsequent ternary complex formation with integrins and IGFR1 are essential for IGF1 signaling. Induces the phosphorylation and activation of IGFR1, MAPK3/ERK1, MAPK1/ERK2 and AKT1 (PubMed : 19578119, PubMed : 22351760, PubMed : 23243309, PubMed : 23696648). As part of the MAPK/ERK signaling pathway, acts as a negative regulator of apoptosis in cardiomyocytes via promotion of STUB1/CHIP-mediated ubiquitination and degradation of ICER-type isoforms of CREM (By similarity).
See full target information IGF1

其他靶点

IGF1R,IGF2,IGF2R,IGFBP1,IGFBP2,IGFBP3,IGFBP4,IGFBP6,INS

文献 (1)

Recent publications for all applications. Explore the full list and refine your search

Molecular medicine reports 24: PubMed34184083

2021

M2‑like tumour‑associated macrophage‑secreted IGF promotes thyroid cancer stemness and metastasis by activating the PI3K/AKT/mTOR pathway.

Applications

Unspecified application

Species

Unspecified reactive species

Juan Lv,Chao Liu,Fu-Kun Chen,Zhi-Ping Feng,Li Jia,Peng-Jie Liu,Zhi-Xian Yang,Fei Hou,Zhi-Yong Deng
View all publications
websiteProtocolBooklet
en
websiteProtocolBooklet
en

Abcam Product Promise

我们致力于为您的研究提供高质量的试剂,为您科研的每一步提供支持。若我们的产品未能达到预期性能,我们向您提供 Abcam Product Promise 保障。
详情请参阅我们的条款与条件。

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com