概述

  • 产品名称Anti-Tetraspanin-33抗体
    参阅全部 Tetraspanin-33 一抗
  • 描述
    兔多克隆抗体to Tetraspanin-33
  • 经测试应用适用于: WB, IHC-Pmore details
  • 种属反应性
    与反应: Human
    预测可用于: Mouse, Cow, Zebrafish
  • 免疫原

    Synthetic peptide conjugated to KLH derived from within residues 250 to the C-terminus of Human Tetraspanin-33.

    (Peptide available as ab87705.)

  • 阳性对照
    • This antibody gave a positive signal in Human Spleen Tissue Lysate.

性能

  • 形式Liquid
  • 存放说明Shipped at 4°C. Store at +4°C short term (1-2 weeks). Upon delivery aliquot. Store at -20°C or -80°C. Avoid freeze / thaw cycle.
  • 存储溶液Preservative: 0.02% Sodium Azide
    Constituents: 1% BSA, PBS, pH 7.4
  • Concentration information loading...
  • 纯度Immunogen affinity purified
  • 克隆多克隆
  • 同种型IgG
  • 研究领域

相关产品

应用

Our Abpromise guarantee covers the use of ab79130 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

应用 Ab评论 说明
WB Use a concentration of 1 mg/ml. Detects a band of approximately 32 kDa (predicted molecular weight: 32 kDa).
IHC-P Use a concentration of 5 µg/ml.

靶标

Anti-Tetraspanin-33 antibody 图像

  • Anti-Tetraspanin-33 antibody (ab79130) at 1 µg/ml + Human spleen tissue lysate - total protein (ab29699) at 10 µg

    Secondary
    Goat polyclonal to Rabbit IgG - H&L - Pre-Adsorbed (HRP) at 1/3000 dilution
    Developed using the ECL technique

    Performed under reducing conditions.

    Predicted band size : 32 kDa
    Observed band size : 30 kDa (why is the actual band size different from the predicted?)


    Exposure time : 5 minutes
  • IHC image of ab79130 staining in Hodgekin's Lymphoma formalin fixed paraffin embedded tissue section, performed on a Leica BondTM system using the standard protocol F. The section was pre-treated using heat mediated antigen retrieval with sodium citrate buffer (pH6, epitope retrieval solution 1) for 20 mins. The section was then incubated with ab79130, 5µg/ml, for 15 mins at room temperature and detected using an HRP conjugated compact polymer system. DAB was used as the chromogen. The section was then counterstained with haematoxylin and mounted with DPX.

    For other IHC staining systems (automated and non-automated) customers should optimize variable parameters such as antigen retrieval conditions, primary antibody concentration and antibody incubation times.

Anti-Tetraspanin-33 antibody (ab79130)参考文献

This product has been referenced in:

See 1 Publication for this product

Product Wall

There are currently no Abreviews or Questions for ab79130.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"