兔Anti-Rat IgG H&L (FITC) preadsorbed (ab7100)

概述

  • 产品名称兔Anti-Rat IgG H&L (FITC) preadsorbed
    参阅全部 IgG 二抗
  • 靶标种属Rat
  • 经测试应用适用于: ICC/IF, IHC-P, IHC-Fr, Immunomicroscopy, Flow Cyt, ELISAmore details
  • 最小交叉反应
    Human more details
  • 免疫原

    Full length native Rat IgG (purified).

  • 偶联物FITC. Ex: 493nm, Em: 528nm

性能

  • 形式Liquid
  • 存放说明Shipped at 4°C. Store at +4°C.
  • 存储溶液pH: 7.40
    Preservative: 0.01% Thimerosal (merthiolate)
    Constituents: 0.42% Potassium phosphate, 0.88% Sodium chloride, 1% BSA
  • Concentration information loading...
  • 纯度IgG fraction
  • 纯化说明This product was prepared from monospecific antiserum by immunoaffinity chromatography using Rat IgG coupled to agarose beads followed by solid phase adsorption(s) to remove any unwanted reactivities.
  • 共轭说明Diaminotriazinylaminofluorescein (DTAF) (Molecular Weight 530 daltons) Absorption Wavelength: 495 nm Emission Wavelength: 528 nm Fluorochrome/Protein Ratio: 2.3 moles DTAF per mole of Rabbit IgG
  • 克隆多克隆
  • 研究领域

应用

Our Abpromise guarantee covers the use of ab7100 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

应用 Ab评论 说明
ICC/IF
IHC-P
IHC-Fr
Immunomicroscopy
Flow Cyt
ELISA
  • 应用说明Flow Cyt: Use at an assay dependant concentration.
    IHC-P: Use at an assay dependant concentration.
    IHC-Fr: Use at an assay dependant concentration.
    IM: Use at an assay dependant concentration.

    Not tested in other applications.
    Optimal dilutions/concentrations should be determined by the end user.
  • Rabbit Anti-Rat IgG H&L (FITC) preadsorbed (ab7100)参考文献

    ab7100 has not yet been referenced specifically in any publications.

    Product Wall

    Thank you very much for your reply.

    I've looked at the package'stracking information, and it arrived on September 20 at 9:34 EST. You can track the package on FedEx.com with tracking number: ***. It was signed for by ***- does that help you t...

    Read More

    Thank you very much for your reply.

    It does sound like the secondary is reacting with the IgG's in the mouse serum. I'm sending a free of charge vial of ab6115 on the order *** which should arrive tomorrow.

    Please keep me updated ab...

    Read More

    Thank you very much for contacting us with your question.

    It is possible that the secondary antibody is causing some background signal, as ab7100 has been pre-adsorbed only against human serum proteins and not mouse serum proteins. Have you d...

    Read More

    Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"