小鼠IgG1单克隆抗体 (Phycoerythrin) -同型对照  (ab81200)

概述

  • 产品名称
    小鼠IgG1单克隆抗体 (Phycoerythrin) -同型对照 
    参阅全部 Mouse 亚类对照
  • 偶联物
    Phycoerythrin. Ex: 488nm, Em: 575nm
  • 共轭说明
    R-PE exitation wavelength 488 nm, emission wavelength 575 nm is the correct sentence.
  • 特异性
    This isotype is intended for in vitro use to identify the amount of nonspecific binding of mouse monoclonal antibodies on human cells by flow cytometric methods.
  • 经测试应用
    适用于: Flow Cytmore details
  • 常规说明
    Reagents should be brought to room temperature (22 ± 3°C) before use.

性能

  • 形式
    Liquid
  • 存放说明
    Shipped at 4°C. Store at +4°C short term (1-2 weeks). Upon delivery aliquot. Store at -20°C long term.
  • 存储溶液
    Preservative: 0.1% Sodium Azide
    Constituents: 4mg/ml BSA, 300mM Sodium chloride, 20mM Sodium phosphate
  • Concentration information loading...
  • 纯度
    IgG fraction
  • 纯化说明
    Purified from mouse myeloma
  • 克隆
    单克隆
  • 同种型
    IgG1
  • 研究领域
  • 别名
    • Mouse Isotype Control

应用

Our Abpromise guarantee covers the use of ab81200 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

应用 Ab评论 说明
Flow Cyt Use at an assay dependent concentration.

Nonspecific binding in flow cytometric methods of various diseases.

文献

This product has been referenced in:
  • Bauer K  et al. Slit-2 facilitates interaction of P-cadherin with Robo-3 and inhibits cell migration in an oral squamous cell carcinoma cell line. Carcinogenesis 32:935-43 (2011). Read more (PubMed: 21459757) »

See 1 Publication for this product

客户评价及客户问答

Thank you for contacting Abcam.

Please find attached the Certificate of Compliances that were requested.

If there is anything else I can help you with, please let me know.

Thank you for contacting us.

As requested, I have included the Certificate of Compliance for each of the products listed.

I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or ...

Read More

Thank you for contacting us. If you are not able to easily pellet the exosomes, I would indeed recommend to add 20 µl of the antibody solution to the exosomes in 100 µl PBS. You may need to increase the incubation time and or the volume of ab81436 a...

Read More

Thank you for contacting us. I can confirm that the PE-conjugated CD81 antibody ab81436 is designed for Flow Cytometry analysis of human blood cells, and if the volume of your whole blood sample is 100 µl as indicated, we would suggest the following...

Read More

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"

注册