概述

  • 产品名称MDR Assay试剂盒(Fluorometric)
    参阅全部 MDR 试剂盒
  • 测试
    1 x 96 well plate
  • 样品类型
    Adherent cells, Suspension cells
  • 检测类型Quantitative
  • 检测时间
    1h 0m
  • 种属反应性
    与反应: Human
  • 产品概述

    Multi drug resistance (MDR) is a major factor in the failure of many forms of chemotherapy. In the past few years it has become widely accepted that the resistance to chemotherapy correlates with the overexpression of at least two ATP dependent drug efflux pumps. These cell membrane proteins, called P-glycoprotein (Pgp, MDR1), and multidrug resistance associated protein (MRP1) are members of the ABC transporter family. Abcam's Fluorimetric MDR Assay Kits use a fluorescent MDR indicator for assaying these two MDR pump activities. This hydrophobic fluorescent dye molecule rapidly penetrates cell membranes and becomes trapped in cells. Following a short incubation, the intracellular free dye concentration can increase significantly. In the MDR1 and/or MRP1-expressing cells this dye is extruded by the MDR transporters, thus decreasing the cellular fluorescence intensity. However, when its extrusion is blocked by an agent that interferes with the MDR1 and/or MRP1 pump-activity, its cellular fluorescence intensity increases significantly. Abcam's Fluorimetric MDR Assay Kits are ideal for high throughput screening of MDR pump inhibitors or identifying the cells that have high level of MDR pump activities.

    Visit our FAQs page for tips and troubleshooting.

  • 说明

    Store ab112142 dessicated.

  • 经测试应用适用于: Functional Studiesmore details

性能

    应用

    Our Abpromise guarantee covers the use of ab112142 in the following tested applications.

    The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

    应用 Ab评论 说明
    Functional Studies Use at an assay dependent concentration.

    MDR Assay Kit (Fluorometric) 图像

    • Effect of Cyclosporin A on the inhibition of P-gp pump in MCF7/ADR cells. The increased concentration of Cyclosporin A resulted in an increase in fluorescence signal caused by the inhibition of P-gp pump which enhanced the intracellular accumulation of MDR indicator dye. The EC50 = 2.4 µM (measured with the kit) is similar to the value reported in the literature.

    实验方案

    MDR Assay Kit (Fluorometric) (ab112142)参考文献

    This product has been referenced in:
    • Wang S  et al. Evodiamine synergizes with doxorubicin in the treatment of chemoresistant human breast cancer without inhibiting P-glycoprotein. PLoS One 9:e97512 (2014). Functional Studies . Read more (PubMed: 24830744) »

    See 1 Publication for this product

    Product Wall

    The correct assay method for the kit ab112142 is read from bottom (fluorescence intensity in live cells) using a microplate with opaque wall (black or white) but a transparent bottom. The fluorescence intensity will increase (inside of the live cells) ...

    Read More

    We do not have in-house data for non-adherent cells but customers have reported using the assay with that kind of sample successfully. We do not have their data though. As far as we know, getting good results with cells in suspension is no more difficu...

    Read More

    Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"