概述

  • 产品名称
    人VEGF ELISA试剂盒
    参阅全部 VEGFA 试剂盒
  • 检测方法
    Colorimetric
  • 样品类型
    Cell culture supernatant, Serum, Plasma
  • 检测类型
    Sandwich (quantitative)
  • 灵敏度
    < 10 pg/ml
  • 范围
    8.23 pg/ml - 6000 pg/ml
  • 复检

    > 100 %

    特定样本复检结果
    样品类型 平均% 范围
    Cell culture supernatant 103.5 92% - 113%
    Serum 104.4 92% - 115%
    Plasma 105.7 93% - 114%

  • 实验步骤
    Multiple steps standard assay
  • 种属反应性
    与反应: Human
  • 产品概述

    Abcam’s VEGF Human ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of Human VEGF in serum, plasma and cell culture supernatants.

    This assay employs an antibody specific for Human VEGF coated on a 96-well plate. Standards and samples are pipetted into the wells and VEGF present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-Human VEGF antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of VEGF bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.

  • 说明

    Optimization may be required with urine samples.

  • 经测试应用
    适用于: Sandwich ELISAmore details
  • 平台
    Microplate

性能

应用

Our Abpromise guarantee covers the use of ab100662 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

应用 Ab评论 说明
Sandwich ELISA Use at an assay dependent concentration.

图片

  • VEGF measured in biological fluids showing quantity (pg) per milliliter of sample tested

  • Curves showing concentrations huVEGF165 in NIBSC 02/286 using ab100662 VEGF human

     

  • Representative standard curve using ab100662

  • Representative standard curve using ab100662

实验方案

文献

This product has been referenced in:
  • Tong M  et al. Micro- and Nano-vesicles from First Trimester Human Placentae Carry Flt-1 and Levels Are Increased in Severe Preeclampsia. Front Endocrinol (Lausanne) 8:174 (2017). Read more (PubMed: 28790977) »
  • Van Pham P  et al. Significant improvement of direct reprogramming efficacy of fibroblasts into progenitor endothelial cells by ETV2 and hypoxia. Stem Cell Res Ther 7:104 (2016). Read more (PubMed: 27488544) »

See all 4 Publications for this product

客户评价及客户问答



Please find below the information regarding the source/host of our capture and detection antibodies used in our VEGF Human ELISA Kit (ab100662):

Capture Antibody: Monoclonal Mouse IgG2B

Detection Antibody: Polyclonal Goat I...

Read More


Please note that ab100662 and ab100663 are similar kits that both measure levels of VEGF.

However ab100662 is best used for detecting VEGF in biological fluids such as cell culture supernatant, serum and plasma while ab100663 is best sui...

Read More

Unfortunately we no longer test urine as part of the validation. However the kit is very likely to work for urine (based on our past experience with this sample type).

Here are so some general guidelines on preparation of urine for ELISA tes...

Read More



Capture Antibody: Monoclonal, mouse. The immunogen sequence is Ala27­Arg191 (Accession # NP_001165097.1) Detects human VEGF165 and human VEGF121. In ELISAs, this antibody has ˜10% cross­reactivity with recombinant mouse VEGF and rat V...

Read More



The VEGFA isoform that ab100662 detects is 165 and 121.



Answer 1:

Please use 1X Assay Diluent B to dilute the detection antibody and the HRP-Streptavidin. If testing serum/plasma, use Assay Diluent A to prepare/dilute the standards and samples. Where it says use the “appropriate as...

Read More

Thank you for contacting us.

I can confirm that Heparin should not be interfering with the assay using these kits.

I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or informat...

Read More

Te pido disculpas por la espera.

He recibido una contestación de mis compañeros, que me comentan que la dilución recomendada para suero y plasma debe hacerse entre 2 y 5 veces.

En cualquier caso, los niveles de ...

Read More


Please note this product is unpublished so when you decide to order you need to contact our customer service team for them to put this item in your order.

I hope this info will help. Please let me know if you experience any difficulties.

This product is available but not published on our website. You cannot purchase this using our normal ordering system however I can add this product to your next shipment. Could you confirm how many vials customer would need..6?.
In my last I made...

Read More

1-10 of 14 Abreviews or Q&A