Anti-HLA class 2 DQ6抗体[4i147] (ab42130)

概述

  • 产品名称Anti-HLA class 2 DQ6抗体[4i147]
  • 描述
    小鼠单克隆抗体[4i147] to HLA class 2 DQ6
  • 特异性ab42130 reacts to HLA Class 2 Antigen DQ6. Additional crossreactivity occurs with related proteins. Specificity was determined at a 1:10 dilution by the microcytotoxicity test under standard NIH conditions.
  • 经测试应用适用于: Flow Cyt, Microcytotoxicity testing, Functional Studiesmore details
  • 种属反应性
    与反应: Human
  • 免疫原

    HLA class 2 antigen DQ6 (Human)

  • 常规说明


    Cell death will occur in any test well where the HLA cell surface antigen is recognized by its matched anti-HLA antibody. Live lymphocytes indicate a negative reaction. Dead lymphocytes indicate a positive reaction. Limitations: Cell isolation difficulties, contamination of the lymphocyte preparation with red blood cells, monocytes, platelets or granulocytes, cell concentrations outside acceptable levels, bacterial contamination and/or change in pH of antisera may cause erroneous results.

性能

  • 形式Liquid
  • 存放说明Shipped at 4°C. Store at +4°C short term (1-2 weeks). Add glycerol to a final volume of 40% for extra stability and aliquot. Store at -20°C. Avoid freeze / thaw cycle.
  • 存储溶液Preservative: None
    Constituents: 1% BSA, PBS
  • Concentration information loading...
  • 纯度Ascites
  • Primary antibody说明Cell death will occur in any test well where the HLA cell surface antigen is recognized by its matched anti-HLA antibody. Live lymphocytes indicate a negative reaction. Dead lymphocytes indicate a positive reaction. Limitations: Cell isolation difficulties, contamination of the lymphocyte preparation with red blood cells, monocytes, platelets or granulocytes, cell concentrations outside acceptable levels, bacterial contamination and/or change in pH of antisera may cause erroneous results.
  • 克隆单克隆
  • 克隆编号4i147
  • 同种型IgM
  • 研究领域

应用

Our Abpromise guarantee covers the use of ab42130 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

应用 Ab评论 说明
Flow Cyt Use at an assay dependent concentration. ab91545-Mouse monoclonal IgM, is suitable for use as an isotype control with this antibody.
Microcytotoxicity testing Use at an assay dependent concentration.

Add 0.9ml of 1% BSA in PBS to 100µl of 10X antibody stock solution.

Functional Studies Use at an assay dependent concentration.

Cell Typing, Tissue Staining and Chimerism Studies.

Anti-HLA class 2 DQ6 antibody [4i147] (ab42130)参考文献

ab42130 has not yet been referenced specifically in any publications.

Product Wall

There are currently no Abreviews or Questions for ab42130.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"