Key features and details
- Assay type: Quantitative
- Detection method: Colorimetric/Fluorometric
- Platform: Microplate reader
- Assay time: 1 hr
- Sample type: Cell culture supernatant, Other biological fluids, Plasma, Serum, Tissue Extracts, Urine
概述
-
产品名称
Cholesterol/ Cholesteryl Ester Assay试剂盒- Quantitation
参阅全部 Cholesterol/Cholesteryl Ester 试剂盒 -
检测方法
Colorimetric/Fluorometric -
样品类型
Cell culture supernatant, Urine, Serum, Plasma, Other biological fluids, Tissue Extracts -
检测类型
Quantitative -
检测时间
1h 00m -
产品概述
Cholesterol/ Cholesteryl Ester Assay Kit ab65359 provides a simple method for sensitive quantification of total cholesterol, free cholesterol, and cholesteryl esters, by colorimetric or fluorometric methods.
The majority of cholesterol in blood is in the form of cholesteryl esters. In the cholesterol assay protocol, these are hydrolyzed to cholesterol by cholesterol esterase. Cholesterol is then oxidized by cholesterol oxidase to yield H2O2 which reacts with a sensitive cholesterol probe to produce color (λmax = 570 nm) and fluorescence (Ex/Em = 535/587 nm).
The assay detects total cholesterol (cholesterol and cholesteryl esters) when cholesterol esterase is included in the reaction, or free cholesterol when it is not included. The amount of cholesteryl ester can be determined by subtracting the value of free cholesterol from the total (cholesterol plus cholesteryl esters).
Cholesterol assay protocol summary:
- add samples and standards to wells
- add total cholesterol reaction mix (with esterase) or free cholesterol reaction mix (without esterase) and incubate for 60 min at 37ºC
- analyze with microplate reader -
说明
This product is manufactured by BioVision, an Abcam company and was previously called K603 Total Cholesterol and Cholesteryl Ester Colorimetric/Fluorometric Assay Kit. K603-100 is the same size as the 100 test size of ab65359.
Other cholesterol assay kits include:
- HDL and LDL/VLDL Cholesterol assay kit ab65390
- Cell-based Cholesterol assay kit ab133116
- Cholesterol Efflux assay kit ab196985
- Cholesterol Uptake assay kit ab236212Review our Metabolism Assay Guide to learn about assays for metabolites, metabolic enzymes, mitochondrial function, and oxidative stress, and also about how to assay metabolic function in live cells using your plate reader.
Abcam has not and does not intend to apply for the REACH Authorisation of customers’ uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses. -
平台
Microplate reader
性能
-
存放说明
Store at -20°C. Please refer to protocols. -
组件 100 tests 2000 tests Assay Buffer II 1 x 25ml 20 x 25ml Cholesterol Esterase 1 vial 20 vials Cholesterol Standard 1 x 100µl 20 x 100µl Enzyme Mix I 1 vial 20 vials OxiRed Probe 1 x 200µl 20 x 200µl -
研究领域
-
相关性
Cholesterol is an essential molecule in all animal life. It is involved in both normal development and diseases. A high level of serum cholesterol is an indicator for diseases such as heart disease. Cholesteryl ester is an ester of cholesterol. The ester bond is formed between the carboxylate group of a fatty acid and the hydroxyl group of cholesterol.
相关产品
-
Related Products
图片
-
Assessment of free and total cholesterol and cholesteryl ester levels useing ab65359. Protein levels of geranylgeranyldiphosphate synthase were measured by ELISA. Absolute amounts of CoQ10 were measured by HPLC as described in Materials and Methods. Cholesterol levels were quantified using a Cholesterol/Cholesteryl Ester Detection Kit from Abcam according to instruction. n?=?6, means ±SEM. Two-way ANOVA with Tukey's post-hoc test. * denotes statistical comparison between vehicle control (V) and high dose (H) and # denotes statistical comparison between water and ethanol treated groups. * and **, indicate significant difference at p<0.05, 0.01 and 0.0001, respectively. OWV; obese water vehicle, OWH; obese water high dose, OEV; obese ethanol vehicle, OEH; obese ethanol high dose.
-
Total cholesterol (free and ester forms) were determined with a cholesterol quantification assay (fluorometric detection) (ab65359) and are shown relative to untreated control cells.
-
Cholesterol and cholesteryl ester were quantified colourimetrically in biological fluids (dilution range 1:10-1:100; 50 minutes incubation) and measured in duplicates (+/- SD).
-
Detection of Cholesterol/Cholesteryl Ester Using Cholesterol Quantitation Kit (ab65359). Cholesterol/Cholesteryl Ester was quantified using the kit by colorimetric (A) and fluorometric (B) methods according to the kit instructions. Background from the control reaction (without cholesterol) has been subtracted from each value. Note: Fluorometric assay is over 10 fold more sensitive than colorimetric assay.
数据表及文件
-
SDS download
-
Datasheet download
文献 (160)
ab65359 被引用在 160 文献中.
- Xu C et al. Adaptive activation of EFNB2/EPHB4 axis promotes post-metastatic growth of colorectal cancer liver metastases by LDLR-mediated cholesterol uptake. Oncogene 42:99-112 (2023). PubMed: 36376513
- Stierwalt HD et al. Rats with high aerobic capacity display enhanced transcriptional adaptability and upregulation of bile acid metabolism in response to an acute high-fat diet. Physiol Rep 10:e15405 (2022). PubMed: 35923133
- Ng MYW et al. The cholesterol transport protein GRAMD1C regulates autophagy initiation and mitochondrial bioenergetics. Nat Commun 13:6283 (2022). PubMed: 36270994
- Zhang F et al. Crocin ameliorates atherosclerosis by promoting the reverse cholesterol transport and inhibiting the foam cell formation via regulating PPAR?/LXR-a. Cell Cycle 21:202-218 (2022). PubMed: 34978526
- Cui J et al. Alternate Day Fasting Improves Endothelial Function in Type 2 Diabetic Mice: Role of Adipose-Derived Hormones. Front Cardiovasc Med 9:925080 (2022). PubMed: 35711339